Monday 26 May 2008

What is Ashman Phenomenon?

Ashman phenomenon is an aberrant ventricular conduction due to a change in QRS cycle length. In 1947, Gouaux and Ashman reported that in atrial fibrillation, when a relatively long cycle was followed by a relatively short cycle, the beat with a short cycle often has right bundle-branch block (RBBB) morphology. This causes diagnostic confusion with premature ventricular complexes (PVCs). If a sudden lengthening of the QRS cycle occurs, the subsequent impulse with a normal or shorter cycle length may be conducted with aberrancy.
Pathophysiology
Ashman phenomenon is an intraventricular conduction abnormality caused by a change in the heart rate. This is dependent on the effects of rate on the electrophysiological properties of the heart and can be modulated by metabolic and electrolyte abnormalities and the effects of drugs.
The aberrant conduction depends on the relative refractory period of the conduction tissues. The refractory period depends on the heart rate. Action potential duration (ie, refractory period) changes with the R-R interval of the preceding cycle; shorter duration of action potential is associated with a short R-R interval and prolonged duration of action potential is associated with a long R-R interval. A longer cycle lengthens the ensuing refractory period, and, if a shorter cycle follows, the beat ending it is likely to be conducted with aberrancy.
Aberrant conduction results when a supraventricular impulse reaches the His-Purkinje system while one of its branches is still in the relative or absolute refractory period. This results in slow or blocked conduction through this bundle branch and delayed depolarization through the ventricular muscles, causing a bundle-branch block configuration (ie, wide QRS complex) on the surface ECG, in the absence of bundle-branch pathology. A RBBB pattern is more common than a left bundle-branch block (LBBB) pattern because of the longer refractory period of the right bundle branch.
Several studies have questioned the sensitivity and specificity of the long-short cycle sequence. Aberrant conduction with a short-long cycle sequence has also been documented.
Frequency
United States
No geographic variations occur. Ashman phenomenon is related to the underlying pathology and is a common ECG finding in clinical practice.

History
The diagnosis of Ashman phenomenon is made using ECG evaluation findings. Patients may be asymptomatic or may have symptoms of the underlying cardiac condition.
Ashman phenomenon, per se, causes no symptoms. Symptoms, if present, are related to the premature complexes and are not related to whether the complexes are conducted aberrantly.

Physical
No specific physical examination findings are described for Ashman phenomenon.
Pulse findings may include an irregular pulse, tachycardia, and/or pulse deficit in atrial fibrillation.

Causes
Conditions causing an altered duration of the refractory period of the bundle branch or the ventricular tissue cause Ashman phenomenon. These conditions are commonly observed in (1) atrial fibrillation, (2) atrial tachycardia, and (3) atrial ectopy.

Read more about it HERE

1 comment:

maggie.danhakl@healthline.com said...

Hello Ira,

Healthline just designed a virtual guide of how atrial fibrillation affects the body. You can see the infographic here: http://www.healthline.com/health/atrial-fibrillation/effects-on-body

This is valuable med-reviewed information that can help a person understand the effects of afib of their body. I thought this would be of interest to your audience, and I’m writing to see if you would include this as a resource on your page: http://medicalfact.blogspot.com/2008/05/what-is-ashman-phenomenon.html

If you do not believe this would be a good fit for a resource on your site, even sharing this on your social communities would be a great alternative to help get the word out.

Thanks so much for taking the time to review. Please let me know your thoughts and if I can answer any questions for you.

All the best,
Maggie Danhakl • Assistant Marketing Manager
p: 415-281-3124 f: 415-281-3199

Healthline • The Power of Intelligent Health
660 Third Street, San Francisco, CA 94107
www.healthline.com | @Healthline | @HealthlineCorp

About Us: corp.healthline.com

Grey Matter - from the writers of Grey's Anatomy